RSSB2751 - T1167 - WP2 - Testing the effectiveness of detonators - Tender Deadline Extended to January 4th 2019 12:00 Mid-Day
Key facts
- Estimated value
- £80,000
- Closing date
- 04 Jan 2019
- Contract starts
- 21 Jan 2019
- Contract ends
- 31 May 2019
- Procedure
- Open procedure (below threshold)
- Buyer type
- Utilities & transport
Description
Detonators are small metal devices that contain a small quantity of explosives, that are placed on the railhead to cause a loud sound, activated by the wheel-rail interface of a passing train to alert the driver they are approaching a hazard on the line ahead (RSSB GE/GN8532, 2015). During track possessions, detonators are intended to provide a safety protection method if for example a train has been incorrectly signalled into a worksite or to mitigate unauthorised engineering trains exiting the worksite. For detonators to be effective, they must be clearly audible so necessary precaution and mitigation action can be taken. The Rail Group Standard GM/RT2160 (RSSB, 2010) mandates the requirements for the audibility of detonators in driving cabs, and states that: "Driving cabs shall have acoustic characteristics that ensure that exploding detonators, as specified in BR 0640A, can be heard inside the cab at any vehicle speed and readily distinguished from background noise" (p. 5). In a live running railway, it is expected there are a variety of circumstances that will affect the audibility of detonators. T315 workstream 1: noise exposure of staff in driving cabs (RSSB, 2004) suggest sources of driving cab noise include rolling noise, traction and ancillary equipment noise, aerodynamic noise, warning horns, in-cab audible warnings, air-conditioning equipment and heater fans. These, and other factors such as environmental conditions (e.g. weather), insulation of the cab, and subjective comfort, may influence the extent in which detonators are audible to the driver. Detonators that are not clearly audible to the driver may exacerbate safety risks, if they are not alerted to a hazard or possession on the line ahead. T326 Good Practice Guide for the design of alarms and alerts (RSSB, 2008) note that warning alarms must be heard against background noise but should not exceed noise tolerance limits. Ambient noise should be no greater than 85dB(A) for any length of time, and alarms should be between 15 and 25dB(A) above the ambient noise, which in total, should not generally exceed about 110dB(A). As detonators provide a warning alert that is activated externally to the cab, given variable factors that may influence the audibility of detonators, it is unknown in what conditions detonators are clearly audible to the driver. It is also possible that audibility of detonator activation may alert track workers of an approaching train. The extent in which detonators may be audible to track workers is likely to vary depending on conditions such as distance of working from detonator placement, weather, personal protective equipment (ear protection) and machinery in use. However, little evidence is currently available to determine whether detonators provide such secondary function, and what, if any, conditions may influence their effectiveness in being audible to track workers.
Categories (CPV)
Similar open tenders
Supply of Aluminium Sulphate
Location: Yorkshire and the HumberBuyer: YORKSHIRE WATER SERVICES LIMITED
Open tenderCloses 28 Nov, 202623 daysValue £28.60mSource Find a TenderThree plus three year extension option for the Supply of Aluminium Sulphate • The objective of this Procurement Process is to establish an agreement for the delivery of Aluminium Sulphate used for Clean sites. • This framework agreement is envisaged to be the primary route for selecting suppliers for the delivery of th
Supply of Lab Consumables
Location: North EastBuyer: CENTRE FOR PROCESS INNOVATION LIMITED
Open tenderCloses 2 Dec, 202627 daysSource Find a TenderCPI is currently seeking to appoint suitably qualified and experienced suppliers to support our laboratory operations through the provision of a comprehensive range of laboratory consumables. This includes, but is not limited to, general laboratory plasticware, chemicals, glassware, specialist laboratory consumables, a
The Supply and Delivery of Chlorine Gas
Location: United KingdomBuyer: Scottish Water
Open tenderCloses 27 Nov, 202622 daysValue £2.40mSource Find a TenderSupply and Delivery of Chlorine Gas.
Vehicle and Plant Spare Parts Supply for Corserv Solutions Ltd
Location: South WestBuyer: CORSERV SOLUTIONS LIMITED
Open tenderCloses 27 Nov, 202622 daysValue £6.40mSource Find a TenderThis procurement project aims to select and appoint parts suppliers to a Framework Agreement, for the supply of Vehicle and Plant Spare Parts Supply predominantly to Corserv Solutions (Cormac Fleet division) or any of its directorates that wishes to access this agreement.
Custom Phosphoramidites and Succinates
Location: North EastBuyer: CENTRE FOR PROCESS INNOVATION LIMITED
Open tenderCloses 16 Nov, 202611 daysValue £173.00kSource Find a TenderCPI is a UK technology innovation centre and the process element of the Government’s High Value Manufacturing Catapult. We use applied knowledge in science and engineering combined with state-of-the-art facilities to enable our clients to develop, prove, prototype and scale-up the next generation of products and proces
Custom Phosphoramidites and Succinates
Location: North EastBuyer: CENTRE FOR PROCESS INNOVATION LIMITED
Open tenderCloses 16 Nov, 202611 daysValue £173.00kSource Find a TenderCPI is a UK technology innovation centre and the process element of the Government’s High Value Manufacturing Catapult. We use applied knowledge in science and engineering combined with state-of-the-art facilities to enable our clients to develop, prove, prototype and scale-up the next generation of products and proces